Why two different vendors

The FCU-6C has two IMUs: an ST LSM6DSK320X (IMU1) and a Bosch BMI270 (IMU2). The Pixhawk 6C also uses IMUs from two vendors. Two sensors from the same vendor share the same MEMS structure, the same design weaknesses and similar resonant frequencies, so a particular vibration or temperature change can fool both in the same way. Different vendors reduce that common-cause risk and make ArduPilot's IMU consistency checks more meaningful.

There is also a footprint for a third IMU, unpopulated by default. All three use the same 2.5 × 3 mm LGA-14 land. Because the BMI270 has the same pin order as the ST part, switching IMU2 to Bosch did not change the board layout. The one difference is that Bosch forbids tying its auxiliary-interface pins to GND, so those pins are left open.

    Two sensors on one bus, and a patch

    The two IMUs share the SPI1 bus, and that revealed an interesting trap: if the ST IMU's I2C/I3C interface stays enabled, it can read SPI traffic meant for the other sensor as I2C even while its chip select is inactive, and pull the MOSI line (SDA in I2C terms). ArduPilot's driver did not write the bit that disables that interface. We wrote a small patch that does; it is part of our firmware build and we plan to propose it to ArduPilot.

    Different vendors also mean different axis conventions. The BMI270's axes are rotated 90° relative to the ST part, so the two IMUs have different ROTATION values in the board definition. That is why it matters that both IMUs show the same sign in the tilt test at first power-up.

      The heated IMU island

      The IMUs sit at the front end of the board on a 21 × 12 mm island, separated from the rest of the board by two 1.2 mm slots. The island connects to the FMU through a bridge about 9.5 mm wide, which carries the IMU signals and the heater supply. Four 150 Ω 1206 resistors surround the IMUs. In parallel they draw about 133 mA from 5 V, dissipating 0.67 W, and the FMU drives them through a MOSFET on the underside of the island. ArduPilot holds the island at 45 °C.

      Why heat at all? MEMS accelerometer and gyro offsets drift with temperature; a board calibrated on a cool morning can behave differently in the afternoon sun. Holding the IMU at a fixed temperature above ambient keeps the calibration valid whatever the weather was when you did it. The slots keep the heat on the island, so the heater warms only the island, not the whole board. A side benefit is that mechanical stress from the mounting screws does not reach the IMUs.

        Not a vibration isolator

        It is worth being clear about what the island is not: it is not a vibration isolator. The island is short and thick with a resonance in the kHz range, so it does not damp motor and propeller vibration. You still need a vibration-damped mount for the flight controller, and you should still check ArduPilot's vibration logs.

        The heater current loop is kept small and sits about 20 mm from the magnetometer, where its effect is negligible. The barometer is on the bottom side, out of light and airflow.

          What this means for setup

          These notes are based on design data and calculations. Once the prototypes are on the bench we will measure warm-up time and temperature stability and update this post.

          • Wait for the IMU temperature to settle at 45 °C before calibrating.
          • The IMUs are about 31 mm ahead of the board centre; enter the INS_POS offsets relative to the vehicle's centre of gravity.
          • The heater control gains (BRD_HEAT_P/I) come from values chosen for the Pixhawk 6C's insulated IMU board. Our island behaves differently, so these will be retuned during prototype testing; if you see the temperature oscillate, let us know.
          • The LSM6DSK320X driver is currently in ArduPilot master; a backport to 4.7 is pending.